.. _SupportedDevices: ################# Supported devices ################# This page lists the supported devices and their REST API module contracts. The RestApiModule is an application running on the gateway that enables interaction with devices linked to the gateway. Access to the RestApiModule API is enabled by the GW Cloud API. See :ref:`GW Cloud API concepts ` for more information. Barcode scanner, Newland FM3056 ******************************* **Supported platforms** * gateway **Supported hardware** * 4-080503-0013-000 **Supported RestApiModule contracts** * :ref:`BarcodeScanner ` Barcode scanner, Newland FM3281 ******************************* **Supported platforms** * gateway **Supported hardware** * 4-080503-0013-000 **Supported RestApiModule contracts** * :ref:`BarcodeScanner ` * :ref:`RFIDScanner ` Input Output module - Alphatronics AP286 **************************************** **Supported platforms** * gateway **Supported hardware** * 3-020301-0286-000 * hardware interfaces: rs485 (TODO: productnumbers interfaces...) See :ref:`Alphatronics AP298, AP338, AP286 configuration ` to learn more about the advised configuration setup for this device in combination with the HALAPI. **Supported RestApiModule contracts** * :ref:`Outputs ` - **OUTD1 ... OUTD4** : 4 relays (value 0 or 1) * :ref:`Inputs ` - **IND1 ... IND4** : 4 general purpose digital inputs or (directional aware or non-aware) triggers for passage counters (value 0 or 1) * :ref:`Memory ` - **MEM1 ... MEM4** : 4 passage counters (directional aware or non-aware). Max value depends on memory type (will be reset to 0 in case of overflow). All :ref:`memory types and data sizes ` are supported. .. tip:: Memory and/or Input event support is dependent on the loaded script. Possible output parameter values: .. table:: +----------+--------+-------+--------+-------+--------------------------------------------------------------------+ | | | | | | | | State | Value1 | Time1 | Value2 | Time2 | Result | +----------+--------+-------+--------+-------+--------------------------------------------------------------------+ | Reset | x | x | x | x | Persistent set to value 0 | +----------+--------+-------+--------+-------+--------------------------------------------------------------------+ | Toggle | x | x | x | x | Not supported | +----------+--------+-------+--------+-------+--------------------------------------------------------------------+ | Set | [0,1] | 0 | 0 | 0 | Set persistently to Value1 | +----------+--------+-------+--------+-------+--------------------------------------------------------------------+ | Set | [0,1] | >100 | 0 | 0 | Set to Value1 for x ms, then persistent set to value 0 (Set Pulse) | +----------+--------+-------+--------+-------+--------------------------------------------------------------------+ | Interval | [0,1] | >100 | [0,1] | >100 | Set to Value1 for x ms, then set to Value2 for | | | | | | | x ms and repeat this endlessly. | +----------+--------+-------+--------+-------+--------------------------------------------------------------------+ RFID and barcode scanner - STid (custom project) ************************************************* **Supported platforms** * gateway **Supported hardware** * 4-080511-0001-000 (barcodeScanner / rfidscanner / indicators) * 4-080502-0024-000 (rfidscanner / indicator) **Supported RestApiModule contracts** * :ref:`BarcodeScanner ` * :ref:`RFIDScanner ` RFID scanner - Alphatronics AP298 ********************************************** **Supported platforms** * gateway **Supported hardware** * 3-020301-0298-000 **Supported RestApiModule contracts** * :ref:`Outputs ` : for possible output parameter values, see AP286 device - **OUTD1** : 1 relay (value 0 or 1) * :ref:`Inputs ` - **IND1** : 1 general purpose digital input * :ref:`RFIDScanner ` RFID scanner - Alphatronics AP338 ********************************* **Supported platforms** * gateway **Supported hardware** * 3-020301-0298-000 **Supported RestApiModule contracts** * :ref:`Outputs ` : for possible output parameter values, see AP286 device - **OUTD1** : 1 relay (value 0 or 1) * :ref:`Inputs ` - **IND1 ... IND3** : 3 general purpose digital inputs (input1 can be used to connect a pushbutton) * :ref:`RFIDScanner ` Input Output module - WuT Web IO 57738 ************************************** **Supported platforms** * gateway **Supported hardware** * 4-080404-0008-000 **Supported RestApiModule contracts** * :ref:`Inputs ` : - **IND1 ... IND12** : respectively linked to IN0...IN11 * :ref:`Outputs ` : - **OUTD1 ... OUTD8** : respectively linked OUT0...OUT7 * :ref:`Memory ` - **MEM1 ... MEM12** : respectively linked to IN0...IN11. It is possible to configure the counters for bidirectional counting (for example, count only if IN1 is triggered and released after IN0 is triggered and released within a configured time). Possible output parameter values: .. table:: +----------+--------+-------+--------+-------+------------------------------------------------------------------+ | | | | | | | | State | Value1 | Time1 | Value2 | Time2 | Result | +----------+--------+-------+--------+-------+------------------------------------------------------------------+ | Reset | x | x | x | x | Persistent set to value 0 | +----------+--------+-------+--------+-------+------------------------------------------------------------------+ | Toggle | x | x | x | x | Not supported | +----------+--------+-------+--------+-------+------------------------------------------------------------------+ | Set | [0,1] | 0 | 0 | 0 | Set persistently to Value1 | +----------+--------+-------+--------+-------+------------------------------------------------------------------+ | Set | 1 | 100 | 0 | 0 | Pulse for a fixed time (Time1 is ignored, but must be >= 100) | +----------+--------+-------+--------+-------+------------------------------------------------------------------+ | Interval | x | x | x | x | Not supported | +----------+--------+-------+--------+-------+------------------------------------------------------------------+ ANPR - Avutec Module-X IR (custom project) ****************************************** **Supported platforms** * gateway **Supported hardware** * 4-070101-0009-100 **Supported RestApiModule contracts** * :ref:`ANPR ` Input Output module - Alphatronics Gateway ****************************************** **Supported platforms** * gateway **Supported hardware** * 1-040199-0007-000-000-00 * 1-040199-0009-000-000-00 * 1-040199-0012-000-000-00 * 1-040199-0013-000-000-00 **Supported data contracts** * :ref:`Inputs ` : - **IND1 ... IND4** : respectively linked to IN0...IN4 * :ref:`Outputs ` : - **OUTD1 ... OUTD4** : respectively linked OUT0...OUT3 Possible output parameter values: .. table:: +----------+--------+-------+--------+-------+------------------------------+ | | | | | | | | State | Value1 | Time1 | Value2 | Time2 | Result | +----------+--------+-------+--------+-------+------------------------------+ | Reset | x | x | x | x | Persistent set to value 0 | +----------+--------+-------+--------+-------+------------------------------+ | Toggle | x | x | x | x | Toggles between 1 and 0 | +----------+--------+-------+--------+-------+------------------------------+ | Set | [0,1] | 0 | 0 | 0 | Set persistently to Value1 | +----------+--------+-------+--------+-------+------------------------------+ | Set | 1 | 100 | 0 | 0 | Pulse for Time1 [100,300000] | +----------+--------+-------+--------+-------+------------------------------+ | Interval | x | x | x | x | Not supported | +----------+--------+-------+--------+-------+------------------------------+ Display - Alphatronics Gateway ****************************** **Supported platforms** * gateway **Supported hardware** * 1-040199-0008-000-000-00 * 1-040199-0009-000-000-00 * 1-040199-0011-000-000-00 * 1-040199-0013-000-000-00 **Supported RestApiModule contracts** * :ref:`Display `